(For further information on spectroscopy, see:
http://speclab.cr.usgs.gov)
TITLE: H2O-Ice GDS136 DESCRIPT
DOCUMENTATION_FORMAT: VOLATILE
SAMPLE_ID: GDS136
MATERIAL_TYPE: Oxide
MATERIAL: Water_Ice (Frost)
FORMULA: H2O
FORMULA_HTML: H2O
COLLECTION_LOCALITY: USGS Denver Spectroscopy Laboratory faucet
ORIGINAL_DONOR: made from triply distilled H2O, USGS
CURRENT_SAMPLE_LOCATION: none (evaporated)
ULTIMATE_SAMPLE_LOCATION: none (evaporated)
SAMPLE_DESCRIPTION:
The sample was created by growing ice on a 77K cold finger from water vapor from triply distilled H2O from Gary Olhoeft's lab, USGS, Denver. The sample should have very little contaminants; being essentially pure H2O.
Measured at 77K.
END_SAMPLE_DESCRIPTION.
XRD_ANALYSIS:
END_XRD_ANALYSIS.
COMPOSITIONAL_ANALYSIS_TYPE: Other # XRF, EM(WDS), ICP(Trace), WChem
COMPOSITION KEYWORD |
Oxide ASCII |
Amount | Weight Percent, % |
Oxide html |
---|---|---|---|---|
COMPOSITION: | H2O | 100.0 | wt% | H2O |
COMPOSITION: | LOI | 100.0 | wt% | LOI |
COMPOSITION: | Total | 100.0 | wt% | |
COMPOSITION: | O=Cl,F,S | 0.0 | wt% | #correction for Cl, F, S |
COMPOSITION: | New Total | 100.0 | wt% |
COMPOSITION_TRACE: None
COMPOSITION_DISCUSSION:
See sample_discussion above. The ice is very pure, certainly at a level that no contaminants could be detected with spectroscopy.
END_COMPOSITION_DISCUSSION.
MICROSCOPIC_EXAMINATION:
END_MICROSCOPIC_EXAMINATION.
SPECTROSCOPIC_DISCUSSION:
END_SPECTROSCOPIC_DISCUSSION.
SPECTRAL_PURITY: 1a2_3_4_ # 1= 0.2-3, 2= 1.5-6, 3= 6-25, 4= 20-150 microns
LIB_SPECTRA_HED: | where | Wave Range | Av_Rs_Pwr | Comment |
---|---|---|---|---|
LIB_SPECTRA: | splib04a r 1900 | 0.2-3.0µm | 200 | g.s.= |
LIB_SPECTRA: | splib05a r 9212 | 0.2-3.0µm | 200 | g.s.= |
LIB_SPECTRA: | splib06a r 26841 | g.s.= |